Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
J Craniofac Surg ; 22(6): 2359-61, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22134278

RESUMO

OBJECTIVE: The aim of this clinical report was to present and discuss the clinical procedure and the treatment considerations of prosthetic rehabilitation for hemimaxillectomy patients. DESIGN: A 61-year-old man was successfully treated with all the remaining teeth reconstruction including replacing the implant-supported anterior fixed prosthesis and maxillary obturator. CONCLUSIONS: An appropriate obturator design, remaining teeth reconstruction, and establishment of a proper vertical dimension of occlusion are important for acceptable facial appearance and patient satisfaction.


Assuntos
Coroas , Prótese Dentária Fixada por Implante , Arcada Parcialmente Edêntula/reabilitação , Procedimentos Cirúrgicos Ortognáticos/métodos , Obturadores Palatinos , Implantação Dentária Endóssea , Assimetria Facial/etiologia , Fibroma Ossificante/cirurgia , Humanos , Masculino , Neoplasias Maxilares/cirurgia , Pessoa de Meia-Idade , Ajuste de Prótese , Tratamento do Canal Radicular , Tomografia Computadorizada por Raios X , Extração Dentária , Dimensão Vertical
2.
Artigo em Inglês | MEDLINE | ID: mdl-21439865

RESUMO

OBJECTIVE: This study tested the hypothesis that there would be differences in primary stability due to the presence of self cutting blades. We investigated the effect of a self-cutting blade implant design on the primary stability of tapered dental implants in a simulated low-density bone model. STUDY DESIGN: Implant fixtures with 2 different designs, one with self-cutting blades and the other without self-cutting blades, were fabricated in the same implant system. Insertion torque, resonance frequency analysis, reverse torque, and pull-out and push-in tests were evaluated in grade no. 10 solid rigid polyurethane foam. RESULTS: All 5 assessments of the group without self-cutting blades were significantly higher than those of the self-cutting group (P < .001). CONCLUSIONS: The implants without self-cutting blades create a lateral compression with increased contact surface area and consequently improve the primary stability in a simulated low-density bone model.


Assuntos
Implantação Dentária Endóssea/instrumentação , Implantes Dentários , Planejamento de Prótese Dentária , Retenção em Prótese Dentária , Falha de Restauração Dentária , Processo Alveolar/cirurgia , Densidade Óssea , Implantação Dentária Endóssea/métodos , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA